Protection Grading & Arc Flash

IPSA comes with an extensive library of protection devices which can be quickly added to the network. Time-current coordination graphs can be plotted to determine the grading margins between protection relays, fuses and other characteristics such as motor start curves and cable or transformer damage curves.

Software developed specifically for your needs

The IPSA Overcurrent Protection Grading module is maintained to meet the up-to-date industry standards. This module is accompanied by Arc flash module, which meets the current IEEE & NFPA standards to ensure the safety of network components.

Key features of Overcurrent Protection Grading.

Modelling of protection devices

Changeable protection device parameters

Protective Device Modeller (PDM) database

Why use this module?

Each device can have any number of curves of different types.

Protection groups contain the CTs, fuses, relays for each component.

Device parameters can be varied.

The IPSA 2 Protection Grading module provides a quick, easy and reliable way of analysing protection devices and determining protection relay settings.

This module utilises accurate IPSA 2 fault level calculations to determine device and relay operating times.

Users can add new protection devices or modify existing models using the Protection Device Modeler (PDM) application which is supplied free with all copies of IPSA.

Related Modules

The Transient Stability module enables the user to analyse the dynamic response of an electrical power system to faults and switching operations.

The integrated harmonic analysis module provides harmonic penetration calculations, impedance scans and waveforms.

get started

Start with a free trial

Familiarise yourself with IPSA and its related functionality with standard example networks. Try IPSA free for 14 days.

Overcurrent Protection Grading - A quick, easy and reliable way of analysing protection devices and determining protection relay settings.

The Protection Grading module utilises the accurate IPSA 2 fault level calculations to determine device and relay operating times.

Users can add new protection devices or modify existing models using the Protection Device Modeler (PDM) application which is supplied free with all copies of IPSA.

Module features:

  • Extensive database of relays and characteristics
    • Fuses
    • Overcurrent relays
    • Motor starting curves
    • Damage curves
    • Circuit breakers
  • Protection co-ordination in fault level
    • Time – current curves and operating times are calculated for user defined fault currents
    • Actual fault flow currents calculated by IPSA can also be used to determine operating times
    • Results presented on graphs and in coordination tables
    • Operating time and time between adjacent devices is calculated
  • Optional relay operation in load flow (overloads)
    • Protection devices which may operate in load flow due to overloads or incorrect settings are identified
  • Intertripping of circuit breakers
    • Circuit breakers can be linked to protection devices
    • Operation of the protection relays then causes linked circuit breakers to operate
    • Interstrip logic schemes can be configured to model auto-close bus section schemes and similar
  • Relay operation in transient stability
    • Relay operation can be modelled during transient stability studies
    • Circuit breaker interstrip schemes operate in response to protection relays
    • Cascade tripping of protection devices can be analysed.